100A Magnet Immunity 500mt Miniature 2 Pole High Power Latching Motor Relay for Smart Meter
Cautions of Latching Relay: 1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical
Basic Info
Model NO. | IM-M1001D |
Theory | Electromagnetic Relay |
Usage | Household Appliances Relay, Industrial Control, Energy Meter, Smart Grid |
Phase | 1 |
Electricity Type | Ac |
Number of Pole | 1 |
Load | High Power Relay |
Protective Characteristics | Enclosed Rlay |
Action Principle | Electromagnetic Type |
Size | Miniature |
Type | Electric Parameter Relay |
Product | Motor Control 2 Pole High Power Latching Relay |
Rated Load | 100A, 250VAC |
Coil Voltage | 6~36VDC |
Contact Form | 2A/2b |
Contact Material | Agsno2 |
Color | Black |
Transport Package | Cartons/Pallet |
Specification | 26.5*23.5*15mm |
Trademark | IVY |
Origin | Zhejiang, China |
HS Code | 8536411000 |
Production Capacity | 5, 000, 000.00/ Year |
Product Description
Basic Parameters | Dimension(mm) | 29×24.5×27.1 | |
Weight ( g ) | ≈36g | ||
Ambient Temperature | -45~+85ºC | ||
Contact Parameters | Contact Material | AgSnO2 | |
Contact Arrangement | 2A/2B | ||
Contact Resistance | <1.0mΩ(DC12V/1A) | ||
Contact Load | 250VAC,100A | ||
Max. Switching Current | 100A | ||
Electrical Life | 10000 cycles | ||
Mechanical Life | 80000 cycles | ||
Performance Parameters | Rated Voltage | 12V(Advise pulse width 60-80ms) | |
Max. Driving Voltage | 24V(Advise pulse width 20ms) | ||
Motor Resistance | 32(1±15%)Ω | ||
Vibration | 1.5mm(DA),10~ 50Hz | ||
Shock | 1000m/s²,(100g) | ||
Surge Current | 6000A/10ms | ||
Insulation Resistance | >1000MΩ(500VDC) | ||
Dielectric Strength | Motor to Contact | >4000VAC, 1min | |
Across Open Contact | >2000VAC, 1min | ||
Pole to Pole Contact | >4000VAC, 1min | ||
Picking-up Time | <=40ms | ||
Release Time | <=40ms |
Cautions of Latching Relay:
1.Suggestions of relay's input (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status. 2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or afterthe installation.(2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection isfastened and prevent relay from damages or other safety problems due to temp. Rise..(3)The sampling signal wires of products are limited, please do not pull or torque during installation.
Send to us